Sanitary Ware Installation Guide
1. General Installation Preparation
-
Check all items for cracks, glaze defects, or missing accessories before
installation.
-
Keep installation manuals or templates ready.
-
Use only recommended grade sanitary silicone, anchor bolts, and thread
sealants.
-
Ensure plumbing lines are flushed before connecting
sanitaryware.
2. Wash Basin Installation
Type |
Key Steps |
Wall-Hung Basin |
- Use wall template to mark bolt holes
- Drill & fix anchor bolts securely
- Seal back with silicone, connect waste & tap
|
Countertop Basin |
- Cut counter as per basin shape
- Apply silicone below basin rim
- Connect waste & tap above counter
|
Pedestal Basin |
- Fix basin to wall and rest on pedestal
- Hide pipework inside pedestal
- Seal contact points with silicone
|
-
Always ensure height from finished floor = 800–850 mm for user
comfort.
3. Water Closet (WC) Installation
Type |
Key Steps |
Floor-Mounted (S-trap / P-trap) |
- Place on setout point using manufacturer's template
- Fix using anchor bolts or cement-based adhesive
- Connect to waste pipe with sealing ring
- Apply silicone around base
|
Wall-Hung WC |
- Ensure concealed tank is installed & tested before fixing WC
- Mark bolt points, fix WC on wall carrier frame
- Tighten bolts, connect flush pipe & waste outlet
- Test flush before sealing with silicone
|
-
Standard height from floor to top rim (WC): 400–430 mm
-
For western toilets, test both flush performance and water seal
depth.
4. Urinal Installation
-
Install urinal brackets or frame at recommended height
-
Connect flush inlet and drain outlet.
-
Apply silicone around edges
-
Optional: install urinal partition walls for public use
Ideal height from floor to urinal lip:
-
Men : 610–650 mm
-
Boys: 350–450 mm
5. Silicone Sealing & Final Finishing
-
Use non-staining, waterproof sanitary silicone
-
Seal contact points between sanitaryware and walls/floor
-
Wipe excess before it cures
-
Leave silicone to cure 24 hours before using fixtures
6. Post-Installation Checks
Checklist Item |
What to Check |
Flush Operation |
Strong flow, no leakage from joints |
Water Seal Depth (WC) |
50–75 mm visible water in bowl trap |
Fixing Stability |
No rocking or movement in installed fixtures |
Glaze Cleaning |
Remove adhesive or tape marks gently |
Trap Odor Check |
Ensure proper U-bend seal and air trap |