Test Parameter | ISO | ASTM / ANSI | EN / CE | IS | DIN | AQS Inspection Notes |
---|---|---|---|---|---|---|
Length & Width Accuracy | ISO 10545-2 | — | EN 10545-2 | IS 15622 | — | Measured using digital caliper – tolerance ±0.5% or 2mm |
Thickness Variation | ISO 10545-2 | — | EN 10545-2 | IS 15622 | — | ±10% from declared thickness |
Edge Straightness | ISO 10545-2 | — | EN 10545-2 | IS 15622 | — | ±0.5% variation |
Rectangularity | ISO 10545-2 | — | EN 10545-2 | IS 15622 | — | ±0.5% or 2.0 mm diagonal check |
Surface Flatness | ISO 10545-2 | — | EN 10545-2 | IS 15622 | — | Checked via straight edge & feeler gauge |
Water Absorption | ISO 10545-3 | ASTM C373 | EN 10545-3 | IS 15622 | — | Typically 12%–18% in ceramic wall tiles |
Breaking Strength | ISO 10545-4 | ASTM C648 | EN 10545-4 | IS 15622 | — | Must be ≥600 N – field-tested using tile breaker |
Modulus of Rupture | ISO 10545-4 | ASTM C674 | EN 10545-4 | IS 15622 | — | Must be ≥15 N/mm² – tested if required |
Thermal Shock Resistance | ISO 10545-9 | — | EN 10545-9 | IS 15622 | — | No visible damage after repeated cycles |
Crazing Resistance | ISO 10545-11 | ASTM C424 | EN 10545-11 | IS 15622 | — | Must pass – no hairline cracks in glaze |
Stain Resistance | ISO 10545-14 | ASTM C1378 | EN 10545-14 | IS 15622 | — | Minimum Class 3 – field-tested using marker removal |
Chemical Resistance | ISO 10545-13 | ASTM C650 | EN 10545-13 | IS 15622 | — | Class B minimum – tested if required |
Gloss Value (If PGVT) | — | — | — | — | — | AQS test with gloss meter – typically ≥90 GU |
Visual Defects | ISO 10545-2 | ANSI A137.1 | EN 14411 Annex G | IS 15622 | — | ≥95% of tiles should be visually defect-free |
Test Parameter | ISO | ASTM / ANSI | EN / CE | IS | DIN | AQS Inspection Notes |
---|---|---|---|---|---|---|
Length & Width Accuracy | ISO 10545-2 | — | EN 10545-2 | IS 15622 | — | Must be within ±0.5% or ±2 mm – checked with caliper |
Thickness Variation | ISO 10545-2 | — | EN 10545-2 | IS 15622 | — | ±5% tolerance accepted – checked across 5+ samples |
Edge Straightness | ISO 10545-2 | — | EN 10545-2 | IS 15622 | — | ±0.5% deviation allowed |
Rectangularity (Squareness) | ISO 10545-2 | — | EN 10545-2 | IS 15622 | — | ±0.5% diagonal check – verified with straight edge |
Surface Flatness | ISO 10545-2 | — | EN 10545-2 | IS 15622 | — | Flatness deviation ≤ 0.5% |
Water Absorption | ISO 10545-3 | ASTM C373 | EN 10545-3 | IS 15622 | — | Between 0.5% and 3.0% – tested via soak/dry method |
Breaking Strength | ISO 10545-4 | ASTM C648 | EN 10545-4 | IS 15622 | — | Must be ≥1300 N (for tiles ≥ 7.5 mm thick) |
Modulus of Rupture (MOR) | ISO 10545-4 | ASTM C674 | EN 10545-4 | IS 15622 | — | Must be ≥25 N/mm² |
Abrasion Resistance (PEI) | ISO 10545-7 | ASTM C1027 | EN 10545-7 | IS 15622 | — | PEI Class 3 or higher for floor use |
Stain Resistance | ISO 10545-14 | ASTM C1378 | EN 10545-14 | IS 15622 | — | Must be ≥ Class 3 – marker/chemical stain tested |
Chemical Resistance | ISO 10545-13 | ASTM C650 | EN 10545-13 | IS 15622 | — | Class A or B depending on surface finish |
Slip Resistance | ISO 10545-17 | ANSI A326.3 (DCOF) | EN 14231 | — | DIN 51130 / 51097 | R9–R12 or DCOF ≥ 0.42 – for wet/sloped areas |
Gloss Value (PGVT only) | AQS Test | — | — | — | — | PGVT must be ≥90 GU – measured via gloss meter |
Surface Quality | ISO 10545-2 | ANSI A137.1 | EN 14411 Annex G | IS 15622 | — | ≥95% tiles should be visually perfect |
Test Parameter | ISO | ASTM / ANSI | EN / CE | IS | DIN | AQS Inspection Notes |
---|---|---|---|---|---|---|
Length & Width Accuracy | ISO 10545-2 | — | EN 10545-2 | IS 15622 | — | ±0.3% or ±1.5 mm – checked with digital caliper |
Thickness Variation | ISO 10545-2 | — | EN 10545-2 | IS 15622 | — | ±5% tolerance across all test samples |
Rectangularity | ISO 10545-2 | — | EN 10545-2 | IS 15622 | — | Must be within ±0.3% (diagonal) |
Edge Straightness | ISO 10545-2 | — | EN 10545-2 | IS 15622 | — | ±0.3% or less – verified edge to edge |
Surface Flatness | ISO 10545-2 | — | EN 10545-2 | IS 15622 | — | ≤0.2% warpage – measured across corners and centre |
Water Absorption | ISO 10545-3 | ASTM C373 | EN 10545-3 | IS 15622 | — | Must be ≤ 0.5% – tested using precise soak/dry weighing |
Breaking Strength | ISO 10545-4 | ASTM C648 | EN 10545-4 | IS 15622 | — | ≥1300–2000 N depending on size & thickness |
Modulus of Rupture | ISO 10545-4 | ASTM C674 | EN 10545-4 | IS 15622 | — | Must be ≥35 N/mm² – ensures load resistance |
Abrasion Resistance (PEI) | ISO 10545-7 | ASTM C1027 | EN 10545-7 | IS 15622 | — | PEI Class 3–5 depending on usage |
Stain Resistance | ISO 10545-14 | ASTM C1378 | EN 10545-14 | IS 15622 | — | Must be Class 5 (PGVT) – tested using marker & cleaner |
Slip Resistance | ISO 10545-17 | ANSI A326.3 (DCOF) | EN 14231 | — | DIN 51130 / 51097 | R9–R12 or DCOF ≥ 0.42 – especially for matte/anti-skid |
Gloss Value (Polished) | AQS Test | — | — | — | — | ≥90 GU for PGVT – tested with gloss meter |
Thermal Shock Resistance | ISO 10545-9 | — | EN 10545-9 | IS 15622 | — | Must pass 10+ thermal cycles without cracks |
Frost Resistance | ISO 10545-12 | ASTM C1026 | EN 10545-12 | IS 15622 | — | Required for outdoor use – tested by freeze-thaw cycle |
Surface Quality | ISO 10545-2 | ANSI A137.1 | EN 14411 Annex G | IS 15622 | — | ≥95% tiles must be free from surface defects |
Test Parameter | ISO | ASTM / ANSI | EN / CE | IS | DIN | AQS Inspection Notes |
---|---|---|---|---|---|---|
Length & Width Accuracy | ISO 10545-2 | — | EN 10545-2 | IS 15622 | — | ±0.3% or ±1.5 mm – verified with digital caliper |
Thickness Variation | ISO 10545-2 | — | EN 10545-2 | IS 15622 | — | ±5% – measured from all sides |
Edge Straightness | ISO 10545-2 | — | EN 10545-2 | IS 15622 | — | ±0.3% tolerance – essential for perfect joint alignment |
Rectangularity | ISO 10545-2 | — | EN 10545-2 | IS 15622 | — | Must not exceed ±0.3% – critical for seamless flooring |
Surface Flatness | ISO 10545-2 | — | EN 10545-2 | IS 15622 | — | ≤0.2% warpage – tested with straight edge & feeler gauge |
Water Absorption | ISO 10545-3 | ASTM C373 | EN 10545-3 | IS 15622 | — | ≤0.5% – typically 0.05% to 0.2% in premium batches |
Breaking Strength | ISO 10545-4 | ASTM C648 | EN 10545-4 | IS 15622 | — | ≥1300–2000 N – varies by size & thickness |
Modulus of Rupture | ISO 10545-4 | ASTM C674 | EN 10545-4 | IS 15622 | — | ≥35 N/mm² – ensures high load-bearing capability |
Abrasion Resistance | ISO 10545-6 | — | EN 10545-6 | IS 15622 | — | Must show minimal wear under heavy foot traffic |
Scratch Hardness (Mohs) | — | ASTM C1895 | — | — | — | Mohs ≥ 6 – tested with steel tools during visual QC |
Stain Resistance | ISO 10545-14 | ASTM C1378 | EN 10545-14 | IS 15622 | — | High stain resistance – permanent marker test conducted |
Slip Resistance | ISO 10545-17 | ANSI A326.3 (DCOF) | EN 14231 | — | DIN 51130 / 51097 | R10–R12 or DCOF ≥ 0.42 – mandatory for commercial zones |
Frost Resistance | ISO 10545-12 | ASTM C1026 | EN 10545-12 | IS 15622 | — | Required for outdoor use – must pass freeze-thaw cycles |
Surface Quality | ISO 10545-2 | ANSI A137.1 | EN 14411 Annex G | IS 15622 | — | ≥95% of tiles should be visually free of defects |
Test Parameter | ISO | ASTM / ANSI | EN / CE | IS | DIN | AQS Inspection Notes |
---|---|---|---|---|---|---|
Length & Width Accuracy | ISO 10545-2 | — | EN 10545-2 | IS 15622 | — | ±0.3% or ±1.5 mm – verified with digital caliper |
Thickness Variation | ISO 10545-2 | — | EN 10545-2 | IS 15622 | — | ±5% allowed – field tested across multiple tiles |
Rectangularity | ISO 10545-2 | — | EN 10545-2 | IS 15622 | — | ±0.3% diagonal alignment – key for perfect joint laying |
Surface Flatness | ISO 10545-2 | — | EN 10545-2 | IS 15622 | — | ≤0.2% warp tolerance – checked with feeler gauge |
Water Absorption | ISO 10545-3 | ASTM C373 | EN 10545-3 | IS 15622 | — | Must be ≤0.5% – generally between 0.1–0.3% |
Breaking Strength | ISO 10545-4 | ASTM C648 | EN 10545-4 | IS 15622 | — | Must be ≥1300 N – depending on thickness |
Modulus of Rupture (MOR) | ISO 10545-4 | ASTM C674 | EN 10545-4 | IS 15622 | — | ≥35 N/mm² – confirms tile body strength |
Abrasion Resistance (Deep Abrasion) | ISO 10545-6 | — | EN 10545-6 | IS 15622 | — | Must be < 175 mm³ – ensures high durability under wear |
Slip Resistance | ISO 10545-17 | ANSI A326.3 (DCOF) | EN 14231 | — | DIN 51130 / 51097 | R11–R13 or DCOF ≥ 0.42 – especially for wet/industrial use |
Scratch Resistance | — | ASTM C1895 | — | — | — | Mohs ≥ 6 – verified manually during inspection |
Frost Resistance | ISO 10545-12 | ASTM C1026 | EN 10545-12 | IS 15622 | — | Required for outdoor or low-temp zones – must pass |
Stain Resistance | ISO 10545-14 | ASTM C1378 | EN 10545-14 | IS 15622 | — | Class 5 – unglazed tiles must resist marker/chemical stains |
Chemical Resistance | ISO 10545-13 | ASTM C650 | EN 10545-13 | IS 15622 | — | Class A or B – depending on use environment |
Surface Quality | ISO 10545-2 | ANSI A137.1 | EN 14411 Annex G | IS 15622 | — | ≥95% of tiles must be free from surface damage/variation |
Test Parameter | ISO | ASTM / ANSI | EN / CE | IS | DIN | AQS Inspection Notes |
---|---|---|---|---|---|---|
Length & Width Accuracy | ISO 10545-2 | — | EN 10545-2 | IS 15622 | — | Must be within ±0.3% or ±1.5 mm – critical for fitting |
Thickness Consistency | ISO 10545-2 | — | EN 10545-2 | IS 15622 | — | Checked side-to-side across full tile |
Edge Straightness | ISO 10545-2 | — | EN 10545-2 | IS 15622 | — | ±0.3% – verified with ruler and square edge |
Surface Flatness | ISO 10545-2 | — | EN 10545-2 | IS 15622 | — | Warpage ≤ 0.2% – especially at groove area |
Water Absorption | ISO 10545-3 | ASTM C373 | EN 10545-3 | IS 15622 | — | Must be ≤ 0.5% – ensures durability in outdoor use |
Breaking Strength | ISO 10545-4 | ASTM C648 | EN 10545-4 | IS 15622 | — | ≥1300 N – supports weight of heavy foot traffic |
Modulus of Rupture (MOR) | ISO 10545-4 | ASTM C674 | EN 10545-4 | IS 15622 | — | ≥35 N/mm² – required for step load-bearing areas |
Slip Resistance | ISO 10545-17 | ANSI A326.3 (DCOF) | EN 14231 | — | DIN 51130 / 51097 | R11–R13 or DCOF ≥ 0.42 – grooves must enhance grip |
Groove Accuracy | AQS Visual Check | — | — | — | — | Number of grooves, spacing, and alignment checked visually |
Corner Chipping | AQS Visual Check | — | — | — | — | Inspected at all 4 corners – critical for safety/finish |
Stain Resistance | ISO 10545-14 | ASTM C1378 | EN 10545-14 | IS 15622 | — | Class 4 or 5 required – marker and cleaner test |
Surface Quality | ISO 10545-2 | ANSI A137.1 | EN 14411 Annex G | IS 15622 | — | ≥95% tiles must be visually perfect and chip-free |
Anti-Skid Groove Depth | AQS Custom Check | — | — | — | — | Groove depth verified manually – typically 0.8–1.2 mm |
Test Parameter | ISO | ASTM / ANSI | EN / CE | IS | DIN | AQS Inspection Notes |
---|---|---|---|---|---|---|
Length & Width Accuracy | ISO 10545-2 | — | EN 10545-2 | IS 15622 | — | ±0.3% or ±1.5 mm – checked for all sides |
Thickness Accuracy (20mm) | ISO 10545-2 | — | EN 10545-2 | IS 15622 | — | ±0.5 mm tolerance allowed – verified on multiple pieces |
Rectangularity | ISO 10545-2 | — | EN 10545-2 | IS 15622 | — | Must be within ±0.3% – checked diagonally |
Flatness (Warpage) | ISO 10545-2 | — | EN 10545-2 | IS 15622 | — | ≤0.2% tolerance – checked with straight edge |
Water Absorption | ISO 10545-3 | ASTM C373 | EN 10545-3 | IS 15622 | — | Must be ≤0.5% – typically 0.1–0.3% |
Breaking Strength | ISO 10545-4 | ASTM C648 | EN 10545-4 | IS 15622 | — | ≥10,000 N – required due to 20mm thickness |
Modulus of Rupture (MOR) | ISO 10545-4 | ASTM C674 | EN 10545-4 | IS 15622 | — | ≥45 N/mm² – for load-bearing outdoor applications |
Slip Resistance | ISO 10545-17 | ANSI A326.3 (DCOF) | EN 14231 | — | DIN 51130 / 51097 | R11–R13 or DCOF ≥ 0.42 – essential for wet outdoor areas |
Frost Resistance | ISO 10545-12 | ASTM C1026 | EN 10545-12 | IS 15622 | — | Must pass freeze-thaw cycles – for outdoor performance |
Abrasion Resistance | ISO 10545-6 | — | EN 10545-6 | IS 15622 | — | Must show minimal volume loss – critical for driveways |
Stain Resistance | ISO 10545-14 | ASTM C1378 | EN 10545-14 | IS 15622 | — | Class 5 preferred – ensures cleanability in outdoor use |
Load Bearing Strength | ISO 10545-4 | ASTM C140 | — | — | — | Field-tested with point load setups for elevated flooring |
Surface Quality | ISO 10545-2 | ANSI A137.1 | EN 14411 Annex G | IS 15622 | — | ≥95% of pavers must be free from edge/corner chips |
Pallet Packing | AQS QC Checklist | — | — | — | — | Inspected for slip sheets, corner protection & stacking |
Test Parameter | ISO | ASTM / ANSI | EN / CE | IS | DIN | AQS Inspection Notes |
---|---|---|---|---|---|---|
Length & Width Accuracy | ISO 10545-2 | — | EN 10545-2 | IS 15622 | — | ±0.3% or ±1.5 mm – essential for proper joint alignment |
Thickness Accuracy | ISO 10545-2 | — | EN 10545-2 | IS 15622 | — | Typically 9–12 mm; must be ±0.5 mm |
Rectangularity (Diagonal) | ISO 10545-2 | — | EN 10545-2 | IS 15622 | — | Max. ±0.3% – crucial for continuous laying |
Flatness / Warpage | ISO 10545-2 | — | EN 10545-2 | IS 15622 | — | ≤0.2% – must be checked both lengthwise & widthwise |
Water Absorption | ISO 10545-3 | ASTM C373 | EN 10545-3 | IS 15622 | — | ≤0.5% – most slabs are < 0.1% |
Breaking Strength | ISO 10545-4 | ASTM C648 | EN 10545-4 | IS 15622 | — | ≥2000 N – varies with thickness and size |
Modulus of Rupture (MOR) | ISO 10545-4 | ASTM C674 | EN 10545-4 | IS 15622 | — | ≥35–45 N/mm² – slab must withstand heavy load |
Surface Quality | ISO 10545-2 | ANSI A137.1 | EN 14411 Annex G | IS 15622 | — | ≥95% must be visually perfect – edge & center checked |
Digital Print Alignment | AQS QC Visual | — | — | — | — | Book match / vein match lines must be aligned |
Gloss Value (PGVT slabs) | — | — | — | — | — | ≥90 GU – tested with gloss meter on 5+ points |
Slip Resistance (Matte slabs) | ISO 10545-17 | ANSI A326.3 (DCOF) | EN 14231 | — | DIN 51130 | R10–R12 or DCOF ≥ 0.42 – important for vertical install |
Frost Resistance | ISO 10545-12 | ASTM C1026 | EN 10545-12 | IS 15622 | — | Mandatory for facade use in cold climates |
Stain Resistance | ISO 10545-14 | ASTM C1378 | EN 10545-14 | IS 15622 | — | Class 5 – permanent marker + coffee stain removal |
Handling Quality (Crate Check) | AQS QC Checklist | — | — | — | — | Packing, wooden crate stability, clamp lifting risk checked |
Test Parameter | ISO | ASTM / ANSI | EN / CE | IS | DIN | AQS Inspection Notes |
---|---|---|---|---|---|---|
Length & Width Accuracy | ISO 10545-2 | — | EN 10545-2 | IS 15622 | — | ±0.5% or 1.5 mm – critical for consistent wall joints |
Thickness Accuracy | ISO 10545-2 | — | EN 10545-2 | IS 15622 | — | ±10% variation – measured at center and corners |
Edge Straightness | ISO 10545-2 | — | EN 10545-2 | IS 15622 | — | ±0.5% tolerance – verified using right-angle ruler |
Squareness / Rectangularity | ISO 10545-2 | — | EN 10545-2 | IS 15622 | — | ±0.5% – essential for proper layout grid |
Surface Flatness | ISO 10545-2 | — | EN 10545-2 | IS 15622 | — | Warpage ≤ 0.5% – field tested by laying |
Water Absorption | ISO 10545-3 | ASTM C373 | EN 10545-3 | IS 15622 | — | >10% typical – tested via soaking method |
Breaking Strength | ISO 10545-4 | ASTM C648 | EN 10545-4 | IS 15622 | — | ≥600 N – verified using manual MOR setup |
Surface Quality | ISO 10545-2 | ANSI A137.1 | EN 14411 Annex G | IS 15622 | — | ≥95% tiles must be free from glaze defects & printing errors |
Glaze Uniformity | AQS Visual Test | — | — | — | — | Checked for shine, pinholes, clouding, or smudges |
Shade Variation (Gloss Tiles) | AQS Visual | ANSI A137.1 | — | — | — | Must match master sample – especially in white tiles |
Crackle / Crazing (If intentional) | ISO 10545-11 | — | — | — | — | Crazing must be controlled if part of design (e.g., crackle finish) |
Stain Resistance | ISO 10545-14 | ASTM C1378 | EN 10545-14 | IS 15622 | — | Class 3 minimum – checked for kitchen/bathroom suitability |
Box Label Accuracy | AQS QC Visual | — | — | — | — | Design name, shade, size to match PO & sample |
Test Parameter | ISO | ASTM / ANSI | EN / CE | IS | DIN | AQS Inspection Notes |
---|---|---|---|---|---|---|
Individual Tile Size Accuracy | ISO 10545-2 | — | EN 10545-2 | IS 15622 | — | Must be within ±0.5 mm – verified using caliper |
Sheet Size Consistency | AQS Manual Check | — | — | — | — | 300×300 or 300×600 mm sheets – uniformity checked |
Mesh / Mounting Quality | AQS QC Visual | — | — | — | — | Mesh must be firm, evenly spaced, well-glued |
Thickness Uniformity | ISO 10545-2 | — | EN 10545-2 | IS 15622 | — | Variance ≤ ±5% – especially critical for floor mosaics |
Water Absorption | ISO 10545-3 | ASTM C373 | EN 10545-3 | IS 15622 | — | ≤0.5% (Porcelain BIa) / >10% (Ceramic BIII) |
Breaking Strength (Sheet) | ISO 10545-4 | ASTM C648 | EN 10545-4 | IS 15622 | — | Measured for porcelain body mosaics |
Modulus of Rupture (Tile) | ISO 10545-4 | ASTM C674 | EN 10545-4 | IS 15622 | — | Must meet floor application standards (BIa) |
Slip Resistance (Floor use) | ISO 10545-17 | ANSI A326.3 (DCOF) | EN 14231 | — | DIN 51130 / 51097 | R10–R13 or DCOF ≥ 0.42 (Porcelain only) |
Stain Resistance | ISO 10545-14 | ASTM C1378 | EN 10545-14 | IS 15622 | — | Class 5 (porcelain), Class 3+ (wall ceramic) |
Shade / Gloss Consistency | AQS Visual Check | ANSI A137.1 | — | — | — | Checked tile-to-tile and sheet-to-sheet |
Surface Quality | ISO 10545-2 | — | EN 14411 Annex G | IS 15622 | — | ≥95% must be free of chip, glaze defect, or misprint |
Sheet Cutting & Alignment | AQS Visual Check | — | — | — | — | Must form clean lines; corners must align |
Pallet Packing Protection | AQS QC Checklist | — | — | — | — | Separator between sheets, plastic-wrapped, corner protected |
Test Parameter | ISO | ASTM / ANSI | EN / CE | IS | DIN | AQS Inspection Notes |
---|---|---|---|---|---|---|
Length & Width Accuracy | ISO 10545-2 | — | EN 10545-2 | IS 15622 | — | Must be within ±0.5% – varies by body (BIII or BIa) |
Thickness Consistency | ISO 10545-2 | — | EN 10545-2 | IS 15622 | — | ±5–10% depending on body and finish |
Edge Straightness | ISO 10545-2 | — | EN 10545-2 | IS 15622 | — | Especially important in rectified 3D tiles |
Flatness (for flat models) | ISO 10545-2 | — | EN 10545-2 | IS 15622 | — | Verified by laying – warpage ≤ 0.5% |
Water Absorption | ISO 10545-3 | ASTM C373 | EN 10545-3 | IS 15622 | — | BIII: >10%, BIa: ≤0.5% – verified by soak/dry test |
Surface Detailing Quality | AQS Visual Check | — | — | — | — | Must be free of pinholes, fading, blur, double print |
Design Alignment | AQS Visual Check | — | — | — | — | Especially for multi-tile murals or bookmatch sets |
Color / Gloss Consistency | AQS Visual Check | ANSI A137.1 | — | — | — | Same tone across boxes – checked under white lighting |
Surface Quality | ISO 10545-2 | ANSI A137.1 | EN 14411 Annex G | IS 15622 | — | ≥95% defect-free surface – includes micro dents and chips |
Stain Resistance | ISO 10545-14 | ASTM C1378 | EN 10545-14 | IS 15622 | — | Class 3 minimum (Class 5 preferred for glossy models) |
Crazing Resistance (if glossy) | ISO 10545-11 | ASTM C424 | EN 10545-11 | IS 15622 | — | Must pass – especially for white, glossy, or crackle tiles |
Edge & Corner Protection | AQS QC Checklist | — | — | — | — | Inner packing with foam/paper separators checked |
Box Artwork & Label Accuracy | AQS Visual | — | — | — | — | Design name, color code, size, and batch stickers verified |
Test Parameter | ISO / EN / IS | ASTM | AQS Inspection Notes |
---|---|---|---|
Overall Dimensions | IS 2556-1 / ISO 10093 | — | Checked as per product drawing or client reference |
Mounting Hole Alignment | ISO 10093 | — | Distance between mounting holes checked using tape/calliper |
S-Trap / P-Trap Size | IS 2556 / EN 997 | — | Trap length and diameter verified (standard: 180mm, 230mm etc) |
Flush Volume (WC) | EN 997 | — | Full flush: 6L / Half flush: 3L – visual confirmation only |
Glaze Uniformity | IS 2556 / ISO 10093 | — | Must be smooth, consistent – inspected under light |
Pinholes / Glaze Defects | IS 2556-2 | — | Surface must be ≥95% free from bubbles, specs, dull areas |
Crack-Free Body | IS 2556 / ISO 10093 | — | Tap tested and visual check for hairline cracks |
Load Bearing Strength (WC) | IS 2556-4 / EN 997 | ASTM C1161 | WC pan must withstand ≥400 kg static load |
Water Seal Depth (WC) | EN 997 | — | Minimum 50mm–75mm – confirmed visually during dry QC |
Fixing Holes & Outlet Location | IS 2556 | — | Positions measured to avoid mismatch during installation |
Warping (Basins/WC Base) | ISO 10545-2 (adapted) | — | Base must sit flat on level surface – rocking not allowed |
Logo / Branding Placement | AQS QC Checklist | — | Branding or customer logo placement and quality verified |
Packing Material Check | AQS QC Checklist | — | Checked for corner foam, stretch wrap, box size, stacking |
Product Matching with PO | AQS Verification | — | Shape, model, color must match order and reference sample |
Test Parameter | ISO / EN / IS | ASTM | AQS Inspection Notes |
---|---|---|---|
Length & Width Accuracy | EN 12057 / IS 14223 | ASTM C615 / C503 | ±1 mm for tiles, ±2 mm for slabs – measured using tape and caliper |
Thickness Accuracy | EN 12058 / IS 1130 | ASTM C615 | ±1 mm for 20mm / 30mm slabs – spot checked across batch |
Edge Straightness | EN 12057 | — | Must be ≤1 mm deviation across 1 meter – checked with straight edge |
Rectangularity / Diagonal | EN 12057 | — | Corners must form 90° – verified using L-square |
Surface Finish Quality | ISO 14689 / IS 1130 | ASTM C97 / C1353 | Gloss/hone/flame finish must be uniform – checked visually & by gloss meter |
Gloss Value (Polished Only) | — | ASTM C241 | ≥85 GU (Granite), ≥75 GU (Marble) – measured at multiple spots |
Surface Defects (Pinholes, Pits) | AQS Visual Standard | — | Must be free from visible surface holes or processing marks |
Cracks / Veins / Inclusions | AQS Visual & Tap Check | — | Hairline or deep cracks flagged with chalk – tapping used for detection |
Shade Variation / Color Consistency | ISO 10545-16 | — | Slabs must match within batch – especially important for big installations |
Water Absorption | EN 13755 / IS 1124 | ASTM C97 | Granite: ≤0.5%, Marble: up to 0.8% – tested in lab (or supplier report) |
Flexural Strength | EN 12372 | ASTM C880 | Granite: ≥10 MPa, Marble: ≥7 MPa – factory-tested or verified by lab |
Dry Compressive Strength | EN 1926 / IS 1122 | ASTM C170 | Granite: ≥100 MPa, Marble: ≥80 MPa – reference from supplier/lab |
Edge Finishing (Chamfer/Bevel) | AQS Visual QC | — | Must be clean, straight, with no overcut or chipping |
Packing & Slab Separation | AQS QC Checklist | — | Edge protectors, foam sheets, crate stability checked |
Slab Numbering & Labeling | AQS Custom Practice | — | Slab numbers, dimensions, shade ID & job code label checked |
Test Parameter | ISO / EN / IS | ASTM | AQS Inspection Notes |
---|---|---|---|
Length & Width Accuracy | EN 15285 / IS 15779 | ASTM C485 | Tolerance: ±2 mm – checked slab to slab with measuring tape |
Thickness Accuracy | EN 14617-1 / IS 15779 | ASTM C97 | ±0.5 mm – verified on all 4 edges using caliper |
Rectangularity / Diagonal | EN 14617-16 | — | Corners must be 90° – checked with square scale |
Surface Flatness (Warpage) | EN 14617-17 | ASTM C485 | Must be < 2 mm/meter – tested using straight edge |
Flexural Strength | EN 14617-2 | ASTM C880 | ≥25 MPa – as per factory report or third-party lab testing |
Compressive Strength | EN 14617-15 | ASTM C170 | ≥100 MPa (average) – documented value |
Water Absorption | EN 14617-1 | ASTM C97 | ≤0.05% – very low due to resin system |
Surface Polish (Gloss Value) | ISO / EN | ASTM D523 | ≥90 GU for polished surfaces – tested with gloss meter |
Scratch Resistance (Mohs) | — | ASTM C1895 | Mohs hardness ≥ 6–7 – verified with scratch tool |
Color & Pattern Uniformity | AQS Visual Check | — | No batch variation – critical in marble-look or plain white shades |
Pinholes / Resin Patches | AQS QC Visual | — | Surface must be free of blowholes, filler marks, or resin pits |
Edge Chipping / Finishing | AQS Visual & Manual Check | — | Smooth, clean edges without blade burns or roughness |
Labeling / Slab ID Marking | AQS Checklist | — | Slab size, batch no., shade code & customer ID sticker verified |
Crate Packaging QC | AQS Checklist | — | Foam padding, vertical stacking, strapping, crate nail check |
Test Parameter | ISO / EN / IS | ASTM | AQS Inspection Notes |
---|---|---|---|
Length & Width Accuracy | EN ISO 24337 / IS | ASTM F2421 | Tolerance ±0.15 mm – measured with digital caliper |
Thickness Accuracy | EN ISO 24346 | ASTM F387 | ±0.10 mm tolerance – measured with micrometer |
Squareness / Diagonal Accuracy | EN ISO 24337 | ASTM F2421 | Must be within 0.25 mm – verified with L-square |
Click Profile Precision | AQS Manual Check | — | Male/female profile fit tested on multiple planks |
Wear Layer Thickness | EN 429 | ASTM F410 | 0.3mm / 0.5mm / 0.7mm – measured and verified |
Surface Wear Resistance | EN 660 / ISO 10582 | ASTM D3389 | Must meet Class 31/32/33 depending on usage |
Indentation Resistance | EN ISO 24343-1 | ASTM F1914 | Checked under static load – must recover within 0.1 mm |
Dimensional Stability | EN ISO 23999 | ASTM F2199 | ≤ 0.10% change after heat exposure |
Curling After Heat | EN ISO 23999 | ASTM F2199 | Max 2 mm curl – tested after 6 hrs at 80°C |
Waterproof Test | AQS Internal Test | — | Soaked in water for 24h – must not swell or delaminate |
Color Fastness to Light | ISO 105-B02 | ASTM F1515 | Minimum ≥ Grade 6 (Indoor use) |
Scratch Resistance | EN 660-2 | ASTM D3363 | Must resist light abrasions – verified on matte/wood textures |
Stain Resistance | ISO 105-A02 | ASTM F925 | Coffee, wine, marker stains tested & cleaned |
IXPE Foam Layer Thickness (if applicable) | AQS Check | — | 1 mm – 2 mm measured – also checked for uniformity |
Box Label & Quantity Check | AQS QC Checklist | — | Box label: Design, size, batch, lot ID, pcs/box verified |
Packaging Quality | AQS Checklist | — | Side tape seal, carton shape, corner protection, stretch wrap |